Citation (Citation #: 2023-00005463.24)

General Information

Citation Number:
2023-00005463.24

Date Issued:
Mon, Dec 16, 2024 10:14 AM

Status:
Final Order

Total Citation Amount:
$305.54

Name of Person Cited:
TALOOTS PARTNERSHIP GP

Property in Violation:
423 PARK ROW
BOWLING GREEN KY 42101
PVA Parcel #: 039A05 031

Property Owner:
TALOOTS PARTNERSHIP GP
833 PIPERS LN
BRENTWOOD TN 370278745

Code Compliance Officer:
Sanja Dudaric

Inspection Date:
Mon, Dec 16, 2024 1:00 PM

Code Violations (3)

Exterior Structure

Code:
IPMC 3.304.7 Roofs and Drainage General Requirements / Exterior Structure

Code Description:
The exterior of a structure shall be maintained in good repair, structurally sound and sanitary so as not to pose a threat to the public health, safety or welfare. The roof and flashing shall be sound, tight and not have defects that admit rain. Roof drainage shall be adequate to prevent dampness or deterioration in the walls or interior portion of the structure. Roof drains, gutters and downspouts shall be maintained in good repair and free from obstructions. Roof water shall not be discharged in a manner that creates a public nuisance. Roofing or roofing component have defects that admit rain. Looking from outside the celling in the top floor is caving in.

Dangerous Building

Code:
IPMC 3.304.1.1 Unsafe Conditions General Requirements / Exterior Structure / General

Code Description:
The following conditions shall be determined as unsafe and shall be repaired or replaced to comply with the International Building Code or the International Existing Building Code as required for existing buildings: 1. The nominal strength of any structural member is exceeded by nominal loads, the load effects or the required strength; 2. The anchorage of the floor or roof to walls or columns, and of walls and columns to foundations is not capable of resisting all nominal loads or load effects; 3. Structures or components thereof that have reached their limit state; 4. Siding and masonry joints including joints between the building envelope and the perimeter of windows, doors and skylights are not maintained, weather resistant or water tight; 5. Structural members that have evidence of deterioration or that are not capable of safely supporting all nominal loads and load effects; 6. Foundation systems that are not firmly supported by footings, are not plumb and free from open cracks and breaks, are not properly anchored or are not capable of supporting all nominal loads and resisting all load effects; 7. Exterior walls that are not anchored to supporting and supported elements or are not plumb and free of holes, cracks or breaks and loose or rotting materials, are not properly anchored or are not capable of supporting all nominal loads and resisting all load effects; 8. Roofing or roofing components that have defects that admit rain, roof surfaces with inadequate drainage, or any portion of the roof framing that is not in good repair with signs of deterioration, fatigue or without proper anchorage and incapable of supporting all nominal loads and resisting all load effects; 9. Flooring and flooring components with defects that affect serviceability or flooring components that show signs of deterioration or fatigue, are not properly anchored or are incapable of supporting all nominal loads and resisting all load effects; 10. Veneer, cornices, belt courses, corbels, trim, wall facings and similar decorative features not properly anchored or that are anchored with connections not capable of supporting all nominal loads and resisting all load effects; 11. Overhang extensions or projections including, but not limited to, trash chutes, canopies, marquees, signs, awnings, fire escapes, standpipes and exhaust ducts not properly anchored or that are anchored with connections not capable of supporting all nominal loads and resisting all load effects; 12. Exterior stairs, decks, porches, balconies and all similar appurtenances attached thereto, including guards and handrails, are not structurally sound, not properly anchored or that are anchored with connections not capable of supporting all nominal loads and resisting all load effects; or 13. Chimneys, cooling towers, smokestacks and similar appurtenances not structurally sound or not properly anchored, or that are anchored with connections not capable of supporting all nominal loads and resisting all load effects. Exceptions: 1. When substantiated otherwise by an approved method. 2. Demolition of unsafe conditions shall be permitted when approved by the code official. Roofing or roofing component have defects that admit rain. Looking from outside the celling in the top floor is caving in.

Exterior Structure

Code:
IPMC 3.304.13.1 Glazing General Requirements / Exterior Structure / Window, Skylight & Door Frames

Code Description:
The exterior of a structure shall be maintained in good repair, structurally sound and sanitary so as not to pose a threat to the public health, safety or welfare. Every window, skylight, door and frame shall be kept in sound condition, good repair and weather tight. All glazing materials shall be maintained free from cracks and holes. There is at least one broken/boarded/missing window on a structure at this location.

Suggestions or problems with this page?

Let us know if anything is wrong with this page. However, please don't include any personal or financial information.

Would you like a reply?

We'll only use this to reply to your message.